At this point, has established a huge friendly and mutually beneficial marketing network throughout the world.
CI-PC36 Dew Point Analyzer Product Features
With microprocessor as the core, it has the character-istics of intelligence, good stability and high reliability;
With ultra-thin alumina capacitive sensor as the measuring unit, high precision, long calibration cycle;
Menu lock switch: prevent misoperation to change the analyzer parameters and affect its normal operation;
An alarm will be issued when the dew point value deviates from the alarm value, which can be set arbitrar-
ily in the full scale range.
Technical Index
| Measuring range | -60℃~+20℃ (basic) |
| -80℃~+20℃ (standard) | |
| -100℃~+20℃ (extension) | |
| Linear error | ±3℃(-80~-60℃) |
| ±2℃(-60~+20℃) | |
| Repeatability | ±0.5℃ |
| Zero drift | ±1%FS/7d |
| Range drift | ±1%FS/7d |
| Response time | 63%[90%] range at +20°C and 1bar pressure |
| -60→-20℃ Td 5s[10s] | |
| -20→-60℃ Td 45s[10min] | |
| Power supply | AC 100~240V, 50/60Hz |
| Ambient TEMP. | 0~+45℃ Ambient humidity:<90%RH |
| Sample gas TEMP. | 0~+50℃ |
| Sample gas pressure | Atmospheric conditions±10% (Gas outlet should be atmospheric conditions) |
| Communication | RS485(standard)/RS232(optional) |
| Dimensions | W x H x D=144mm x 144mm x 251mm |
has realized substantial competitive advantage by consistently producing high-quality CHANG AI in a timely way.