Reliable CI-PC91 Trace oxygen analyzer 1
Reliable CI-PC91 Trace oxygen analyzer 1

Reliable CI-PC91 Trace oxygen analyzer

With overpressure protection, when the pressure in the gas path exceeds the pressure protection range, auto-matically cut off the gas path on both sides of the sensor chamber;
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    In tune with the track of market development, the product is widely accepted by customers.

    CI-PC91 Trace Oxygen Analyzer Product Features


    With overpressure protection, when the pressure in the gas path exceeds the pressure protection range, automatically cut off the gas path on both sides of the sensor chamber;

    High precision temperature and pressure automatic

    compensation, reduce the impact of temperature and pressure on the measurement accuracy;

    With over-range protection, when the oxygen concentration is higher than the protection limit value, automatically cut off the gas path on both sides of the sensor chamber, to avoid the sensor long time in the nvironment with high oxygen concentration and affect its performance and life.


      Technical Index


    SensorElectrochemical oxygen sensor
    Measuring range0~10/ 100/ 1000ppm/ 1%/ 25.00% O₂
    Linear error0.01~9.99ppm    O₂ :±5% FS

    10.0~99.9ppm    O₂ :±3% FS

    100~1000ppm    O₂ :±2% FS
    Repeatability0.01~9.99ppm    O₂ :±2.5% FS

    10.0~99.9ppm    O₂ :±1.5% FS

    100~1000ppm    O₂ :±1% FS
    Stability0.01~9.99ppm    O₂ :±2.5% FS/7d

    10.0~99.9ppm    O₂ :±1.5% FS/7d

    100~1000ppm    O₂ :±1% FS/7d
    Response timeT₉₀<60s(25℃)
    Power supplyAC 100~240V, 50/60Hz
    Analog signal2 groups, 4-20mA/0-20mA/0-1V/0-5V/0-10V/

    1-5V can be set mode freely
    Switching signal6 groups,relay contact capacity:DC 24V, 0.2A
    CommunicationRS485(standard)/RS232(optional)
    External control5 groups,control signal DC 9~28V
    Sample gas flow0.5~2L/min (recommended 1.5L/min )

    We are fully confident in the prospect of the future market of this product.

    Recommended
    no data
    Message Form
    Let's Discuss Your Needs
    Our trade account manager team will provide you with seamless full-process assistance, from quotation to delivery, covering every link of project implementation. Professional trade consultants are at your service at any time.
    CHANG AI is a world-leading high-tech enterprise in gas analysis and detection, committed to providing customers with world-class gas analysis and detection products and one-stop solutions.
    Contact Information
    Fax: +86-21-33275656
    Tel: +86-21-51692285 / +86-21 400 700 8817
    Add: No.97, Qibao WanKe International Center, Lane 1333, Xinlong Road, Minhang District, Shanghai, P.R. China. 201101
    Customer service
    detect