Our professional quality team adopts scientific methods and takes strict quality assurance measures.
CI-PC9200 series online gas chromatograph is equipped with high-sensitivity hydrogen flame ionization detector and ultra-long life sample cutting valve, through the action of carrier gas, the samples in methane, total hydrocarbons and benzene series quantitative tubes are sent to the corresponding columns for separation, and then enter the FID detector for analysis, and obtain quasi-definitive quantitative analysis of each single component. The instrument has a compact structure and firm installation, which is suitable for the online analysis and monitoring of volatile organic compounds in industrial exhaust gases under complex and harsh environmental conditions.
CI-PC9200 Online gas chromatograph Product Features
Uses EPC Technology for carrier gas pressure control, accurate and stable pressure control, pressure control accuracy is better than ±0.1kPa;
Uses EFC Technology for hydrogen and air flow control, the flow control accuracy is better than 0.5%FS;
It has automatic ignition when the flame is turned off, and the hydrogen gas is turned off when the ignition fails to ensure the safety of the system. The over-temperature automatic protection function prevents device damage;
Oven control accuracy is better than ±0.1℃;
The ultra-long life cutting valve is adopted, the cutting air flow is stable, the maintenance is low, and the reliable operation can be guaranteed for more than 10 years;
Using a miniature FID detector, its extremely low detection limit (0.01ppm) has ultra-high sensitivity and excellent gravity for various organic waste gases such as total combustion, non-a hospital total combustion, ketones, olefins, alcohols, etc. Reality and high analytical efficiency.
Technical Index
| Measurement components | Methane, Non-Methane Total Combustion, Total Combustion, Benzene, Toluene, Ethyl Benzene, m/p-Xylene, o-Xylene, etc. |
| Detector | High sensitivity fid detector |
| Measuring range | Non-methane total hydrocarbons: 0-200/1000mg/m3 (propane) |
| Benzene series: 0~100mg/m³ (customizable) | |
| FID Detection limit | Non-methane THC 0.05mg/m³(propane), |
| benzene series, 0.35mg/m³ | |
| Linear error | ≤±2%FS |
| Chromatograph-ic column | Packed column |
| Methane/non-methane THC:<2min | |
| Benzene series:<5min | |
| Sample gas TEMP. | Room temperature~150℃ |
| Sample gas flow | >0.5L/min |
| Gas source requirements | Carrier gas: high-purity nitrogen or zero-grade air (>99.999%) |
| Gas: high-purity hydrogen (>99.999%) | |
| Supporting gas: zero-grade air |
Application Field
Petroleum refining; biopharmaceuticals; electronics industry; packaging and printing; paint production; leather printing and dyeing; petrochemical.
Typical Spectra
It is in high accordance with the first-class quality inspection standards.