loading
Top CI-PC93 Portable trace oxygen analyzer 1
Top CI-PC93 Portable trace oxygen analyzer 1

Top CI-PC93 Portable trace oxygen analyzer

CI-PC93 Portable trace oxygen analyzer  Product FeaturesWith overpressure protection, when the pressure in the gas path exceeds the pressure protection range, automatically cut off the gas path on both sides of the sensor chamber;High precision pressure automatic compensation, reduce the impact of pressure on the measurement accuracy;With over range protection, when the oxygen concentration is higher than the protection limit value, automatically cut off the gas path on both sides of the sensor chamber, to avoid the sensor in the high oxygen concentration environment for a long time and a...
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    The product has been tested to be of good performance and durability.

    CI-PC93 Portable trace Oxygen Analyzer  Product Features


    With overpressure protection, when the pressure in the gas path exceeds the pressure protection range, automatically cut off the gas path on both sides of the sensor chamber;

    High precision pressure automatic compensation, reduce the impact of pressure on the measurement accuracy;

    With over range protection, when the oxygen concentration is higher than the protection limit value, automatically cut off the gas path on both sides of the sensor chamber, to avoid the sensor in the high oxygen concentration environment for a long time and affect its performance and life.


    Technical Index


    SensorElectrochemical oxygen sensor
    Measuring range0~10/100/1000ppm/1%/25%  O₂
    Linear error0.01~9.99ppm   O₂:±5% FS
    10.0~99.9ppm   O₂:±3% FS
    100~1000ppm    O₂:±2% FS
    Repeatability0.01~9.99ppm    O₂:±2.5% FS
    10.0~99.9ppm   O₂:±1.5% FS
    100~1000ppm    O₂:±1% FS
    Stability0.01~9.99ppm    O₂:±2.5% FS/7d
    10.0~99.9ppm   O₂:±1.5% FS/7d
    100~1000ppm    O₂:±1% FS/7d
    Response timeT₉₀<60s (25℃)
    Power supplyAC 100~240V, 50/60Hz
    CommunicationRS485(standard)/RS232(optional)
    Ambient TEMP.0~+45℃  Ambient humidity:<80%RH
    Sample gas flow1~1.5L/min(recommended1.2L/min)
    Sample gas pressurePlease refer to CI-PC951 on page 20
    Analog signal1 group ,4-20mA/0-20mA/0-1V/0-5V/0-10V/
    1-5V,can be set mode freely

    We further consolidate its quality by using advanced technology.

    Recommended
    no data
    Message Form
    Let's Discuss Your Needs
    Our trade account manager team will provide you with seamless full-process assistance, from quotation to delivery, covering every link of project implementation. Professional trade consultants are at your service at any time.
    CHANG AI is a world-leading high-tech enterprise in gas analysis and detection, committed to providing customers with world-class gas analysis and detection products and one-stop solutions.
    Contact Information
    Fax: +86-21-33275656
    Tel: +86-21-51692285 / +86-21 400 700 8817
    Add: No.97, Qibao WanKe International Center, Lane 1333, Xinlong Road, Minhang District, Shanghai, P.R. China. 201101
    Customer service
    detect