For the only way to win customers in CHANG AI market is to improve the sense of customer service.
GNL-120-1/-3 Oxygen transmitter Product Features
Advanced digital processing technology, anti-cross interference, high measurement accuracy, good stability, long service life of the sensor;
Wide range test from ppm level to % level;
Communication function: support RS485 or RS232
communication;
Isolated 4-20mA/ analog signal output.
Technical Index
| Sensor | 3D ion flow sensor | |
| Measuring range | GNL-120-1 0-25% O₂ | |
| GNL-120-3 0-10/100/1000ppm ,0-1%/25%O2 | ||
| Linear error | 0.01~99.9ppm | ±10ppm |
| 100~999.9ppm | ±3%FS | |
| 1000~9999ppm | ±3%FS | |
| 1.00%~25.00% | ±3% of measured value | |
| Repeatability | 0.01~99.9ppm | ±5ppm |
| 100~999.9ppm | ±1.5%FS | |
| 1000~9999ppm | ±1.5%FS | |
| 1.00%~25.00% | ±1.5% of measured value | |
| Stability | 0.01~99.9ppm | ±5ppm/7d |
| 100~999.9ppm | ±1.5%FS/7d | |
| 1000~9999ppm | ±1.5%FS/7d | |
| 1.00%~25.00% | ±1.5%/7d of measured value | |
| Response time | T₉₀<60s (after full preheating) | |
| Power supply | DC 24V, 1A | |
| Transmitter power | <20VA | |
| Ambient TEMP. | -10~+50℃ Ambient humidity:<80%RH | |
| Sample gas pressure | Atmospheric conditions±10% |
We are a dealing with CHANG AI.